We ship worldwide — Singapore, Australia, Malaysia, Indonesia, Philippines, India, Middle East & more

Dwyer logo

Dwyer

USAMeasurement & Detection

Dwyer Instruments (USA; est. 1931) manufactures pressure, flow, level, and temperature measurement instruments for industrial HVAC, process control, and combustion applications. The Dwyer catalog is available — the Magnehelic differential-pressure gauges (Series 2000 and 2300), the Mark II inclined-vertical manometers, Photohelic pressure switch/gauges, air-velocity transmitters, and the Capsuhelic and Digihelic digital differential-pressure gauge ranges.

389
In Collection
12,386
Full Catalog
1 Day
Quote Response
USA
Origin
Worldwide Shipping
Air & sea freight
Datasheets on Request
Technical specs & drawings
1-Day Quote Response
Singapore-based team
Show
Page 1 of 9
389 products
← Prev1239Next →

About Dwyer

Dwyer Instruments (USA; est. 1931) manufactures pressure, flow, level, and temperature measurement instruments for industrial HVAC, process control, and combustion applications. The Dwyer catalog is available — the Magnehelic differential-pressure gauges (Series 2000 and 2300), the Mark II inclined-vertical manometers, Photohelic pressure switch/gauges, air-velocity transmitters, and the Capsuhelic and Digihelic digital differential-pressure gauge ranges.

The Magnehelic gauge is the industry-standard instrument for measuring combustion air-filter differential pressure, fan-discharge static pressure, and clean-room pressurisation on industrial sites globally. Maintenance engineers specify the Magnehelic by part number — the Series 2000 (0–0.5" w.c. through 0–100" w.c.) covers over 80% of combustion-air and HVAC filter-monitoring installations. The most-requested Magnehelic ranges plus matching static-pressure probes and mounting accessories are available for prompt supply.

Beyond the Magnehelic, Dwyer's Capsuhelic (Series 4000) and Digihelic (Series DH3) digital gauges serve higher-accuracy and remote-monitoring requirements — the Digihelic provides 4–20 mA output for BMS integration. The Photohelic (Series 3000) combines gauge and switch in a single instrument, commonly used for fan-failure and filter-blockage alarms on commercial air-handling units. The highest-turnover Dwyer SKUs are in stock; less-common ranges and custom-scale variants have a factory lead time on request.

Common Applications

  • Combustion air-filter monitoring — Magnehelic Series 2000 on burner air-intake filter banks
  • Clean-room and pharmaceutical pressurisation — Magnehelic / Capsuhelic differential-pressure gauges
  • HVAC fan-discharge static pressure — Mark II inclined-vertical manometers on AHU test points
  • Filter-blockage alarms — Photohelic Series 3000 combined gauge/switch on air-handling units
  • BMS-integrated pressure monitoring — Digihelic DH3 with 4–20 mA output for building management

Product Lines

Magnehelic Series 2000 differential-pressure gaugesMark II inclined-vertical manometersPhotohelic Series 3000 switch/gaugesCapsuhelic Series 4000 precision gaugesDigihelic DH3 digital gaugesAir-velocity transmitters
Origin: Manufactured in USA

Related brands we carry

Comparable manufacturers in the same product category.

Frequently asked questions

Common questions about Dwyer from 3G Electric.

Are Dwyer products available?

Yes. We carry the Dwyer Instruments portfolio — Magnehelic gauges, Mark II manometers, Photohelic switch/gauges, Capsuhelic and Digihelic digital gauges, and air-velocity transmitters.

Which Dwyer Magnehelic gauge ranges are available?

The most-requested Series 2000 ranges (0–0.5", 0–1", 0–2", 0–5", 0–10", 0–25" w.c.) are typically available on shorter lead times. Extended-range, dual-scale (Pa/w.c.), and high-pressure Magnehelic variants have a factory lead time on request.

What is the difference between a Dwyer Magnehelic and a Capsuhelic?

The Magnehelic (Series 2000) is a mechanical diaphragm gauge with ±2% full-scale accuracy — the industry standard for visual monitoring. The Capsuhelic (Series 4000) uses a precision capsule element for ±1% accuracy and is suited for higher-precision applications. Both mount identically.

Can a Dwyer Photohelic replace a separate gauge and pressure switch?

Yes. The Photohelic Series 3000 combines a Magnehelic-type gauge with high and low set-point switches in a single instrument, eliminating the need for separate gauge and switch installations on fan-failure and filter-blockage alarm circuits.

Does Dwyer offer gauges with electronic output for BMS integration?

Yes. The Digihelic Series DH3 provides 4–20 mA analog output and dual set-point relay contacts for building-management integration. Dwyer also offers standalone differential-pressure transmitters (Series 616, Series 629) for process-control loops.

Does 3G Electric supply Dwyer products?

Yes — 3G Electric (S) Pte. Ltd. supplies Dwyer products. We stock the Dwyer catalog and supply genuine factory-original products with full manufacturer warranty and technical support.