Ariston

Buy Ariston boiler spare parts in Singapore. 10 SKUs in stock at 3G Electric. Same-day delivery from Woodlands warehouse. Order PCM series components and get a quote today.

10
In Collection
12,386
Full Catalog
Show
Page 1 of 1
10 products

About Ariston

Ariston manufactures boiler controls, ignition systems, and thermal safety components for residential and light commercial heating applications. The brand's product portfolio centers on electronic ignition modules, ionization probes, safety thermostats, and control circuits—components integral to gas boiler operation and flame-supervision systems. These parts are specified for integration into boiler assemblies where reliable flame detection and temperature regulation are critical to safe, efficient combustion.

3G Electric stocks a focused range of Ariston boiler spare parts, including electronic ignition ionization units (variants such as DX and SX configurations), VCA safety probes, contact probes, sanitary thermostats (ARX series), thermal safety devices, and select circuit modules. Each component carries an Ariston part number and is held in inventory to support maintenance, repair, and replacement workflows. The product set reflects common failure points and service intervals in boiler systems, enabling plant engineers and maintenance teams to source verified OEM components without extended lead times.

Ariston components are engineered to meet European heating-appliance standards and are compatible with a broad range of boiler models. The electronic ignition and ionization systems detect flame presence through ion-current measurement, reducing reliance on mechanical flame-rod designs. Safety probes and thermostats provide redundant thermal cut-off and over-temperature protection. 3G Electric maintains stock in Singapore and supports global orders, providing technical specifications, part-number cross-reference data, and same-day dispatch capability for routine boiler service and emergency replacement scenarios.

Industrial applications we supply

  • Residential wall-mounted gas boiler maintenance — Ariston electronic ignition ionization and VCA safety probe replacement during annual service
  • Combi boiler hot-water circuit repair — ARX20 sanitary thermostat swap to restore domestic water temperature stability
  • Boiler thermal protection system upgrade — Installation of Ariston safety thermostat and ionization probe to meet modern heating-appliance safety directives
  • Emergency boiler shutdown response — Rapid supply of Ariston contact probe and thermal safety device to restore ignition and over-temp cut-off function
  • Boiler control system diagnostics — Ariston select circuit and ignition module replacement to isolate flame-detection and ignition faults in complex multi-zone heating systems

Related brands we carry

Comparable manufacturers in the same product category.

Frequently asked questions

Common questions about Ariston from 3G Electric.

What is the difference between Ariston electronic ignition ionization DX and SX models?

The DX and SX designations refer to left/right or dual-channel variants of the electronic ignition ionization unit. Both measure ion current at the flame electrode to confirm ignition. The specific variant (DX: SKU PCM02018; SX: SKU PCM02020) must match the boiler's combustion chamber geometry and electrode configuration. Consult the boiler schematic or cross-reference the failed component's part number to select the correct module.

How do Ariston VCA safety probes function in a boiler circuit?

The VCA safety probe (SKU PCM02024, part 243030) is a thermal cut-off device that interrupts the gas valve supply if boiler water temperature exceeds a set threshold, typically 80–90 °C. It operates independently of the main control thermostat, providing secondary over-temperature protection. Upon cooling below the reset point, the probe re-establishes the circuit without manual intervention.

What role does the Ariston sanitary thermostat ARX20 play in boiler operation?

The ARX20 sanitary thermostat (SKU PCM02026, part 564885) modulates boiler water temperature to maintain a user-set setpoint, typically 35–60 °C for domestic hot-water circuits. It opens and closes the gas valve or modulating valve to prevent overheating and ensure consistent outlet temperature. Common in compact, wall-mounted boilers and combi units.

Can Ariston boiler spare parts be ordered individually, and what lead times apply?

Yes. 3G Electric stocks ten Ariston boiler spare-part SKUs individually. Components in inventory are available for same-day or next-business-day dispatch from the Singapore warehouse. Out-of-stock items are sourced via global suppliers; standard lead time ranges from 5–14 days depending on availability and destination.

How do I identify the correct Ariston part number for my boiler repair?

Locate the original component's Ariston part number on the device label or in the boiler's service manual and wiring diagram. Cross-reference it with 3G Electric's catalog (e.g., 995965, 569560, 243030). If the original part number is unclear, provide the boiler model and the component function (e.g., 'ignition probe', 'temperature switch') for verification before ordering.

Are Ariston thermal safety devices adjustable, and what temperature setpoints are available?

The Ariston thermal safety unit (SKU PCM02032, part 570970) is factory-calibrated to a fixed differential (typically 16–10 °C). It is not field-adjustable. Adjustment or recalibration requires specialized equipment and should be performed by the manufacturer. Replacement with an identically calibrated unit ensures code compliance and safe operation.